Energy management for manufacturing
In manufacturing, energy is often the largest variable cost after raw materials. Electricity for lines and utilities, gas for thermal processes, process and cleaning water, fuel for internal logistics: each resource drifts in its own way, and these drifts remain invisible until they are measured at the right level.
BWS Platform collects this consumption data in real time, end use by end use, and matches it with your production activity. OÉRIX, its AI engine, detects deviations, identifies their root cause and recommends quantified actions: you know what to fix, in what order, and what each action delivers.
Where energy losses hide on an industrial site
A significant share of a plant's consumption creates no value: equipment running outside production, drifting settings, leaks in utility networks. These losses are rarely visible on an overall monthly bill; they appear as soon as each end use is measured and compared with production volume.
Motors, pumps and ventilation
The largest electrical end use in most plants. Out-of-cycle operation or overload can be read directly on the load curve.
Compressed air
A costly and often neglected utility: leaks and an excessive pressure setpoint make compressors run unloaded.
Boilers, furnaces and steam
Thermal processes consume gas continuously; a drop in efficiency or unnecessary temperature holding is costly.
Process and cleaning water
Washing, cooling, CIP: volumes vary with production, and leaks go unnoticed without metering by zone.
Industrial refrigeration and HVAC
Refrigeration units, cooling towers and air conditioning drift with fouling and poorly adjusted setpoints.
Internal logistics
Forklifts, machinery and on-site vehicles: fuel can be managed too, in connection with fleet management.
Concrete use cases
Detect an electricity consumption drift
A line can keep consuming outside production cycles: nights, weekends, changeovers. BWS Platform compares the load curve with production periods; OÉRIX flags the deviation, specifies its origin (equipment, schedule, setpoint) and estimates the avoidable cost.
Optimize process water consumption
The platform measures water by zone and by process, relates volumes to production, monitors tank levels and detects leaks or overly long cleaning cycles.
Anticipate equipment failure
A gradual increase in the consumption of a motor or compressor often precedes a failure. Monitoring highlights this abnormal trend and alerts maintenance before the line stops.
Reduce the consumption baseload
The baseload is the power drawn when the plant is not producing. OÉRIX isolates it, lists the equipment that makes it up and recommends schedulable shutdowns.
Control peak demand
Simultaneous start-ups and exceeding the subscribed capacity increase the bill. The platform detects them and helps smooth load demand.
From measurement to proven savings
BWS Platform collects and centralizes the data; OÉRIX turns it into decisions. Applied to an industrial site, the approach follows five steps.
- 01
Detect
Measurement by line and by utility, matched with production orders; alerts as soon as a deviation appears.
- 02
Understand
Root cause analysis: equipment, schedule, setpoint, maintenance or process.
- 03
Recommend
Prioritized actions, each quantified in cost, savings and payback time.
- 04
Plan
Action plans assigned to maintenance and production teams, with deadlines.
- 05
Track & Prove
Before/after measurement of savings and CO₂ avoided, relative to production volume.
Indicators monitored
Indicators relative to activity, to compare periods, lines and sites on a fair basis.
BWS solutions for manufacturing
Applications
They manage their resources with BWS
“ We have been using BWS's solution for energy monitoring for almost 3 years. The result: a reduction of around 18% in our bill.
“ We use the BWS application to monitor our plant's water consumption in real time, which strengthens our control over water resources. Remote control of water tank filling has reduced unnecessary trips, improving efficiency, safety and production continuity.
Frequently asked questions about industrial energy management
How can I reduce a plant's energy consumption?
In three stages: measure each end use (lines, utilities, refrigeration, compressed air), compare consumption with production volume to spot drifts, then correct their cause. BWS Platform handles real-time measurement; OÉRIX detects deviations, identifies the root cause and quantifies each action in ROI.
What is an energy performance indicator (EnPI)?
An EnPI relates consumption to an activity variable, for example kWh per ton or per unit produced. It makes it possible to compare different production periods and to follow an ISO 50001-type approach.
Do existing meters need to be replaced?
No. BWS Platform relies primarily on the meters and PLCs already in place, supplemented if necessary by non-intrusive IoT sensors, installed without stopping production.
How can compressed air leaks be detected?
A leak shows up as a compressor running while production is stopped, or as an abnormal load time. OÉRIX compares these signals with production schedules and flags the deviation with its probable cause.
Does the solution work across several plants?
Yes. All sites are consolidated in a single view, with indicators comparable from one plant to another, in Tunisia and in France.
Book a personalized demo
Discover how BWS Platform, powered by OÉRIX, can help you supervise your industrial sites and durably reduce your costs.