Energy management system (EnMS/EMS)
Software that collects, centralizes and analyzes the energy and resource consumption of one or more sites to monitor and optimize it. BWS Platform is a multi-resource EMS.
Nous utilisons des cookies pour assurer le bon fonctionnement du site et, avec votre accord, mesurer l’audience et améliorer votre expérience. Aucun traceur n’est déposé sans votre consentement. Politique de confidentialité.
The key terms for measuring, analyzing and reducing the electricity, water, gas and fuel consumption of a site or portfolio, from data measurement to standards and proof of savings.
Software that collects, centralizes and analyzes the energy and resource consumption of one or more sites to monitor and optimize it. BWS Platform is a multi-resource EMS.
A connected (Internet of Things) sensor that measures a physical quantity, such as flow, temperature, level or power, and transmits it remotely to a platform, without dedicated data cabling.
A long-range, low-power radio protocol suited to sensors installed on large or hard-to-reach sites. It complements 4G/5G and Wi-Fi depending on field constraints.
Installing meters downstream of the main meter to separately measure a building, zone, line or use. It is the prerequisite for knowing where energy is actually consumed.
The evolution of power demand over time, usually at 10-minute intervals or less. Reading it reveals baseloads, peaks and consumption outside operating hours.
A system that supervises and controls a building's technical equipment: heating, ventilation, air conditioning, lighting. An EMS can use its data to analyze consumption.
A significant gap between measured consumption and expected consumption given activity, occupancy or weather: a leak, equipment left on, a drifting setting, an incipient failure.
A method that traces a symptom, such as overconsumption, back to its real origin: equipment, schedule, setpoint, process or behavior. Correcting the cause prevents the anomaly from recurring. OÉRIX automates this analysis.
A model of a site's “normal” consumption, established over a reference period and adjusted for influencing factors (production, occupancy, degree days). It is used to detect drifts and measure savings.
An indicator of how severe the weather was over a period, calculated from the difference between outdoor temperature and a reference temperature. It makes it possible to compare heating or cooling consumption from one year to the next.
Maintenance triggered by the measured evolution of a piece of equipment (rising consumption, operating time, vibration) rather than by a fixed schedule or a failure, in order to intervene before it stops.
A site's minimum consumption when there is no activity: nights, weekends, closures. A high baseload indicates equipment running unnecessarily or leaks.
A ratio relating consumption to an activity variable: kWh per ton produced, per m², per night, liters of fuel per 100 km. It makes it possible to compare periods and sites on a fair basis.
The maximum electrical power drawn over a period. When it exceeds the capacity subscribed with the supplier, it leads to penalties; smoothing it reduces the bill without reducing activity.
The ratio between active power, which is actually useful, and the apparent power supplied by the grid. A low power factor indicates reactive energy, often billed, and is corrected by power factor compensation.
The ratio between the volume of water consumed and the volume fed into the network. The difference corresponds mainly to leaks; it is the reference indicator for utilities and local authorities.
The lowest water flow measured at night, when demand is minimal. A gradual increase is the most reliable sign of a leak. See water management.
Liters of fuel consumed per 100 km traveled, or per engine hour for machinery. Monitored per vehicle, it reveals prolonged idling, harsh driving and discrepancies between refueling and actual consumption. See fuel management.
A detailed analysis of a site's consumption, equipment and uses, resulting in a quantified action plan. In both France and Tunisia, it is mandatory for companies and establishments above certain thresholds.
The international standard for energy management systems. It structures a continuous improvement approach: energy policy, energy baseline, EnPIs, action plans and verification of results.
A French obligation requiring commercial buildings over 1,000 m² to reduce their energy consumption by 40% by 2030, 50% by 2040 and 60% by 2050 compared with a reference year. Consumption is declared each year on the OPERAT platform.
Tunisia's National Agency for Energy Conservation (Agence Nationale pour la Maîtrise de l'Énergie). It implements the country's energy efficiency policy, oversees mandatory energy audits and supports energy conservation programs.
The ratio between the savings generated by an action and its cost. It is often expressed as a payback period: the number of months needed for the savings to repay the investment. Estimate my savings.
A method that quantifies the actual savings of an action by comparing the consumption measured after the intervention with the adjusted baseline consumption. The international IPMVP protocol is the most widely used framework.
Greenhouse gas emissions not released thanks to a reduction in consumption. It is obtained by multiplying the energy saved by the emission factor of each resource (grid electricity, gas, fuel).
The quantity of CO₂ equivalent emitted per unit of energy consumed, for example in kg CO₂e per kWh or per liter. It varies by resource and, for electricity, by the country's generation mix.
BWS Platform calculates baseload, EnPIs, peaks and CO₂ avoided in real time; OÉRIX explains the drifts and quantifies the actions.